South Ealing Station: – Post Route & SDP Installation

Project: South Ealing Station – Tube Lines Connect Enabling Works at South Ealing Station, Boston Manor Station & Northfields Depot

Client: Tube Lines Limited

Value: Overall £4 Million

 
New trackside cable containment,

New SDP base and antenna base were constructed. The areas when these were installed were cleared of vegetation etc. and excavated.

Type 2 was compacted and reinforcement cages installed incorporating earthing rods. C40 strength concrete was place in purpose made formwork. Rooms within station environment was upgraded and refurbished to house new equipment.

The existing cable run was temporarily restrained whilst the base was excavated. A new cable riser was formed and also new ducts. The existing post route had new metal posts installed to take the new cables.